| IR Series 1KW-3KW LED/LCD |
|
|
| |
Pure Sine Wave Inverter IR 1KW-3KW LED/LCD |
|
|
| |
Main for home and office Appliance such as Computer,lights,TV,refrigerator,fan,air-conditioner,induction cooker;also it can be compatible with generator,motor etc inductive loads. |
|
 |
| |
Main for home and office Appliance such as TV,refrigerator,fan,lights,computer etc. 35A ~70A automatic 3-stage battery charger ● High surge capability ● Durable construction for long life under extreme environmental conditions
Simplified controls with a snap-on cover that protects settings from being accidentally changed Better thermal performance allows full output power to 50°C (122°F) without de-rating High surge capacity starts more difficult loads and handles overload conditions reliably Circuit boards are conformally-coated to protect them from corrosion for longer life & improved reliability Durable powder coated, corrosion resistant steel chassis 1. Compatible for generator , frequency range (40hz to 80hz ) 2. Charge current is Adjustable(25% ,50% ,75%, 100%),it is suitable for different battery. 3. High overload ability of our APC charger is up to 300% rated power(20 sec.). 4. IR pure sine wave inverter adopts low quiescent current, and power saver mode to reduce power consumption to 10W(3s sensing cycle)/3W(30s sensing cycle) *. It can extract max. power from various batteries with different protections, and low voltage trip can be selected (9.5V/10V or 10V/10.5V). 5. Uses PFC(power factor correction) for charger, which has less power consumption than conventional units. 6. It has 15s delay before transfer when AC resumes, and overload protection when our IR pure sine wave inverter equips with generator. 7. 10ms typical transfer time between battery and AC, which guarantees power continuity of IRcharger. Uses selectable input AC voltage (184-253V or 154-253V) for different kinds of loads. 8. Our IRcharger allows start up and through power with depleted batteries. Its powerful charge rate up to 90Amp**. 9. It can offer 3-step intelligent battery charging, and equipped with 8 preset battery type selector for totally flat batteries. 10. LCD status display, battery/AC priority switch, USB communication port are available for our APC pure sine wave inverter,it also has 17 alarms/warnings for easier operation and trouble-shooting, and ability to switch the unit on/off. In addition,select/deselect power saver mode can be used too.
|
|
 |
 |
| Technical Specifications. |
IR Series Power Inverter 1KW-3KW
| Rated Capacity |
1000w |
1500w |
2000w |
3000w | 1.Input
| Model |
120v Models |
230v Models |
| Nominal Voltage |
100V/110V/115V/120V Selectable |
200V/220V/230V/240V Selectable |
| Input Frequency |
Nominal Input Frequency 50Hz/ 60Hz (Auto Detection) Low Line Frequency Re-Connect :58+0.3Hz For 60Hz; 48+0.3Hz For 50Hz; Low Line Frequency Disconnect :57+0.3Hz For 60Hz; 47+0.3Hz For 50Hz; High Line Frequency Re-Connect: 64+0.3Hz For 60Hz; 54+0.3Hz For 50Hz; High Line Frequency Disconnect: 65+0.3Hz For 60Hz; 55+0.3Hz For 50Hz; |
| Efficiency |
>95% (Normal Mode) |
| Noise Filtering |
Full Time EMI/RFI Filtering |
| Over Current Protection |
By Re-Settable Over Current Protector |
| Voltage Range |
| Nominal Input Voltage |
230Vac( Selectable) |
| Low Line Disconnect |
184Vac±4% |
| Low Line Re-Connect |
194Vac ±4% |
| High Line Disconnect |
265Vac±4% |
| High Line Re-Connect |
255Vac±4% |
| Max AC Input Voltage |
270VRMS | | 2.Output
| Rated Power |
1000W |
1500W |
2000W |
3000W |
| Output Voltage |
100V/110V/115V/120V Selectable |
200V/220V/230V/240V Selectable |
| Voltage Waveform |
Pure Sine Wave |
| Crest Factor |
3:1 |
| Output Frequency |
Nominal Input Frequency 50Hz/ 60Hz (Auto Detection) Low Line Frequency Re-Connect : 58+0.3Hz For 60Hz;48+0.3Hz For 50Hz; Low Line Frequency Disconnect : 57+0.3Hz For 60Hz;47+0.3Hz For 50Hz; High Line Frequency Re-Connect: 64+0.3Hz For 60Hz;54+0.3Hz For 50Hz; High Line Frequency Disconnect: 65+0.3Hz For 60Hz;55+0.3Hz For 50Hz; |
| Regulation(Nominal) |
±10% Typical Of Nominal Voltage |
| Transfer Time |
Transfer Time : AC To DC : 10ms (Typical) Transfer Time : DC To AC : 10ms(Typical ) |
Max Bypass Overload Current |
30A | 3.Input
| Nominal Voltage |
DC12V/24V |
DC12V/24V |
DC12V/24V |
DC24V/48V |
| Efficiency |
>80% |
| Noise Filtering |
Full Time EMI/RFI Filtering |
| Over Current Protection |
By Re-Settable Over Current Protector |
| Voltage Range |
| Min DC Start Voltage |
10V/20V/40V |
| Low Battery Alarm |
10.5Vdc ± 0.3Vdc For 12V Battery; 21.0Vdc ± 0.6Vdc For 24V Battery; 42.0Vdc ± 0.6Vdc For 48V Battery |
Low DC Input Shut-Down |
10.0Vdc ± 0.3Vdc For 12V Battery 20.0vdc± 0.6Vdc For 24V Battery; 40.0Vdc± 0.6Vdc For 48V Battery |
High DC Input Alarm& Fault |
16Vdc ± 0.3Vdc For 12V Battery; 32Vdc ± 0.6Vdc For 24V Battery; 64Vdc ± 0.6Vdc For 48V Battery |
High DC Input Recovery |
15.5Vdc ± 0.3Vdc For 12V Battery; 31.0Vdc ± 0.6Vdc For 24V Battery; 62.0Vdc ± 0.6Vdc For 48V Battery | |
| Surge Protection |
(110%<Load<125%) ±10%: Fault (Shutdown Output) After 15 Minutes; (125%<Load<150%) ±10%: Fault (Shutdown Output) After 60s; Load>150% ±10%: Fault (Shutdown Output) After 20s 2000VA / 2700VA:440 Joules 324 Joules 4000VA / 5000VA:660 Joules | 4.Output
| Rated Power |
1000W |
1500W |
2000W |
3000W |
| Output Voltage |
100V/110V/115V/120V Selectable |
200V/220V/230V/240V Selectable |
| Voltage Waveform |
Pure Sine Wave |
| Crest Factor |
3:1 |
| Output Frequency |
| Nominal Input Frequency |
50Hz ± 0.3Hz |
Auto Tracking Main Frequency(Hz) |
50Hz @48-54Hz ; 60Hz @58-64Hz | |
| Regulation(Nominal) |
±10% Typical Of Nominal Voltage |
Regulation (Battery Mode) |
Output Voltage Regulation ±10% Rms |
| Transfer Time |
Transfer Time : AC To DC : 10ms (Typical) Transfer Time: AC To DC : 10ms (Typical ) |
Max Bypass Overload Current |
30A |
| Nominal Input Voltage |
230Vac |
| Input Voltage Range |
196~243Vac |
| Nominal Output Voltage |
According To The Battery Type |
| Nominal Charge Current |
35amp-70amp |
Charge Current Regulation |
± 5Adc |
| Battery Initial Voltage |
0 –15.7 V Dc (Can Operate With 0V Battery) |
Charger Short Circuit Protection |
Circuit Breaker |
Over Charge Protection |
Bat. V ≥ 15.7Vdc/31.4Vdc, Beeps 0.5s Every 1s & Fault After 60s |
| Battery Type |
Lead-Acid 12Ah ~ 250Ah |
| Voltage |
0 –15.7 V DC (Can Operate With 0V Battery) |
| Typical Backup Time |
No Limit,Depend on external battery |
| Charging Method |
Smart Pulse Charging With Two Charging Modes Quick Charging When Battery Is Not Fully Charged, Trickle Charging When Battery Is 90% Fully Charged. |
| Average Charging Current |
35A/20A |
45A/30A |
65A/35A |
75A/30A |
| Protection |
Over Current Protection (SCR Control) Over Charging Voltage Protection (SCR Control) Thermal Protection (CPU Control) | 5.Communications & Management
| Control Panel |
LCD/LED Option |
| Audible Alarm |
Alarm On Battery:Low Battery & Battery Over Voltage Alarm On Abnormal Operation: Over Load, Short-Circuit, & Over Heat |
| Cooling Fan Control |
Temperature Fan,Forced Air, Variable Speed Fan | 6.Environment And Safe
Operating Temperature |
0℃ To 40℃ (32℉ To 104℉) |
Transit/Storage Temperature |
-15℃ To 60℃ |
| Relative Humidity |
5 - 95% Non Condensing |
| Operating Altitude |
0 ~ 3000 Meters |
| Audible Noise |
60 Dba Max at 1m |
| Safety Markings |
CE.FCC |
| EMC |
Class B, EN50091-2, FCC Part15, IEC1000-2-2 |
| Isolation |
1.5kvac For 1 Minute Between Battery And AC Side |
| Quality Control System |
ISO 9001 |
7.Physical
| Dimensions: (H×D×W) |
585*345*312MM |
| N.W/G.W (Kg) |
19 |
19 |
22.5 |
27.5 |
| Packing |
Export Carton For Each Unit Per Carton | |
|
 |
|