  Model No.
  Pure Sine Wave Inverter IR 4KW-6KW LED/LCD
  Typical Application.
  Main for home and office Appliance such as Computer,lights,TV,refrigerator,fan,air-conditioner,induction cooker;also it can be compatible with generator,motor etc inductive loads.
go to top
  Product Feature.
  Main for home and office Appliance such as TV,refrigerator,fan,lights,computer etc. 35A ~70A automatic 3-stage battery charger
● High surge capability
●    Durable construction for long life under extreme environmental conditions Simplified controls with a snap-on cover that protects settings from being accidentally  changed Better thermal performance allows full output power to 50°C (122°F) without de-rating High surge capacity starts more difficult loads and handles overload conditions reliably Circuit boards are conformally-coated to protect them from corrosion for longer life &   improved reliability Durable powder coated, corrosion resistant steel chassis

1. Compatible for generator , frequency range (40hz to 80hz )
2. Charge current is Adjustable(25% ,50% ,75%, 100%),it is suitable for different battery.
3. High overload ability of our APC charger is up to 300% rated power(20 sec.).
4. IR pure sine wave inverter adopts low quiescent current,and power saver mode to reduce power consumption to 10W(3sensing cycle)/3W(30s sensing cycle) *. It can extract max. power from various batteries with different protections, and low voltage trip can be selected (9.5V/10V or 10V/10.5V).
5. Uses PFC(power factor correction) for charger, which has less power consumption than conventional units.
6. It has 15s delay before transfer when AC resumes, and overload protection when our IR pure sine wave inverter equips with generator.
7. 10ms typical transfer time between battery and AC, which guarantees power continuity of IRcharger. Uses selectable input AC voltage (184-253V or 154-253V) for different kinds of loads.
8. Our IRcharger allows start up and through power with depleted batteries. Its powerful charge rate up to 90Amp**.
9. It can offer 3-step intelligent battery charging, and equipped with 8 preset battery type selector for totally flat batteries.
10. LCD status display, battery/AC priority switch, USB communication port are available for our APC pure sine wave inverter,it also has 17 alarms/warnings for easier operation and trouble-shooting, and ability to switch the unit on/off. In addition,select/deselect power saver mode can be used too.
go to top
  Technical Specifications.
IR Series Power Inverter 4KW-6KW

Rated Capacity 4000W 5000W 6000W
1.Input
Model 120v Models 230v Models
Nominal Voltage 100V/110V/115V/120V
Selectable
200V/220V/230V/240V
Selectable
Input Frequency Nominal Input Frequency 50Hz/ 60Hz (Auto Detection)
Low Line Frequency Re-Connect :
58+0.3Hz For 60Hz;48+0.3Hz For 50Hz;
Low Line Frequency Disconnect :
57+0.3Hz For 60Hz;47+0.3Hz For 50Hz;
High Line Frequency Re-Connect:
64+0.3Hz For 60Hz;54+0.3Hz For 50Hz;
High Line Frequency Disconnect:
65+0.3Hz For 60Hz;55+0.3Hz For 50Hz;
Efficiency >95% (Normal Mode)
Noise Filtering Full Time EMI/RFI Filtering
Over Current Protection By Re-Settable Over Current Protector
Voltage Range
Nominal Input Voltage 230Vac( Selectable)
Low Line Disconnect 184Vac±4%
Low Line Re-Connect 194Vac ±4%
High Line Disconnect 265Vac±4%
High Line Re-Connect 255Vac±4%
Max AC Input Voltage 270VRMS
2.Output
Rated Power 4000W 5000W               6000W
Output Voltage 100V/110V/115V/120V Selectable 200V/220V/230V/240V Selectable
Voltage Waveform Pure Sine Wave
Crest Factor 3:1
Output Frequency Nominal Input Frequency 50Hz/ 60Hz (Auto Detection)
Low Line Frequency Re-Connect :
58+0.3Hz For 60Hz;48+0.3Hz For 50Hz;
Low Line Frequency Disconnect :
57+0.3Hz For 60Hz;47+0.3Hz For 50Hz;
High Line Frequency Re-Connect:
64+0.3Hz For 60Hz;54+0.3Hz For 50Hz;
High Line Frequency Disconnect:
65+0.3Hz For 60Hz;55+0.3Hz For 50Hz;
Regulation(Nominal) ±10% Typical Of Nominal Voltage
Transfer Time Transfer Time : AC To DC : 10ms (Typical)
Transfer Time : DC To AC : 10ms(Typical )
Max Bypass 
Overload Current
30A
4.Input
Nominal Voltage DC24V/48V DC48V DC48V
Efficiency >80%
Noise Filtering Full Time EMI/RFI Filtering
Over Current Protection By Re-Settable Over Current Protector
Voltage Range
Min DC Start Voltage 10V/20V/40V
Low Battery Alarm 10.5Vdc ± 0.3Vdc
For 12V Battery;
21.0Vdc ± 0.6Vdc
For 24V Battery;
42.0Vdc ± 0.6Vdc
For 48V Battery
Low DC Input
Shut-Down
10.0Vdc ± 0.3Vdc
For 12V Battery
20.0vdc± 0.6Vdc
For 24V Battery;
40.0Vdc± 0.6Vdc
For 48V Battery
High DC Input
Alarm& Fault
16Vdc ± 0.3Vdc
For 12V Battery;
32Vdc ± 0.6Vdc
For 24V Battery;
64Vdc ± 0.6Vdc
For 48V Battery
High DC Input
Recovery
15.5Vdc ± 0.3Vdc
For 12V Battery;
31.0Vdc ± 0.6Vdc
For 24V Battery;
62.0Vdc ± 0.6Vdc
For 48V Battery
Surge Protection (110%<Load<125%) ±10%: 
Fault (Shutdown Output) After 15 Minutes;
(125%<Load<150%) ±10%: 
Fault (Shutdown Output) After 60s;
Load>150% ±10%:  
Fault (Shutdown Output) After 20s
2000VA / 2700VA:
440 Joules 324 Joules
4000VA / 5000VA:660 Joules
5.Output
Rated Power 4000W 5000W 6000W
Voltage Waveform Pure Sine Wave
Crest Factor 3:1
Regulation (Nominal) ±10% Typical Of Nominal Voltage

Regulation          (Battery Mode)

Output Voltage Regulation ±10% Rms
Transfer Time Transfer Time : AC To DC : 10ms (Typical)
Transfer Time: AC To DC : 10ms (Typical )
Max Bypass
Overload Current
30A
Nominal Input Voltage 230Vac
Input Voltage Range 196~243Vac
Nominal Output Voltage According To The Battery Type
Nominal Charge Current 30Amp-70Amp
Charge Current Regulation ± 5A
Battery Initial Voltage 0 –15.7 V Dc (Can Operate With 0V Battery)
Charger Short
Circuit Protection
Circuit Breaker
Over Charge
Protection
Bat. V ≥ 15.7Vdc/31.4Vdc,
Beeps 0.5s Every 1s & Fault After 60s
Battery Type Lead-Acid 12Ah ~ 250Ah
Voltage 0 –15.7 V DC (Can Operate With 0V Battery)
Typical Backup Time No Limit
Charging Method Smart Pulse Charging With Two Charging Modes:
Quick Charging When Battery Is Not Fully Charged,
Trickle Charging When Battery Is 90% Fully Charged.
Average Charging
Current
65A/35A 70A/40A 50A
Protection Over Current Protection (SCR Control)
Over Charging Voltage Protection (SCR Control)
Thermal Protection (CPU Control)
6.Communications & Management
Control Panel LCD/LED Option
Audible Alarm Alarm On Battery:
Low Battery & Battery Over Voltage
Alarm On Abnormal Operation:
Over Load, Short-Circuit, & Over Heat
Cooling Fan Control Temperature Fan, Forced Air, Variable Speed Fan
7.Environment And Safe
Operating
Temperature
0℃ To 40℃ (32℉ To 104℉)
Transit/Storage
Temperature
-15℃ To 60℃
Relative Humidity 5 - 95% Non Condensing
Operating Altitude 0 ~ 3000 Meters
Audible Noise 60 Dba Max at 1m
Safety Markings CE.FCC
EMC Class B, EN50091-2, FCC Part15, IEC1000-2-2
Isolation 1.5kvac For 1 Minute Between Battery And AC Side
Quality Control System ISO 9001

 

 

 

 

 

8.Physical

Dimensions: (H×D×W) 755*320*310MM
N.W / G.W (Kg) 37.5 47.5 47.5
Packing Export Carton For Each Unit Per Carton
go to top
Copyright © 2004-2012 Shenzhen Mustups Power Limited, All Rights Reserved.