| NT Series 600W-10KW LED/LCD |
|
|
| |
Pure Sine Wave Inverter NT 600W-10KW LED/LCD |
|
|
| |
Low frequency with AVR function which can run most common electrical appliances such as lights, televisions, fan,cash registers, refrigerators, washing machines, computers, and power tools.Mainly use for home and office. |
|
| |
including high reliability, complete protection function, small waveform distortion, low price, etc.
High efficiency and reliability Protection Function ,Computer inspection monitoring
It can convert the 12V/24V48V DC power supply into the purity sine wave AC power supply of voltage stabilizing, frequency stabilizing and low noise of 220V and 50Hz.
This product has higher conversion efficiency (can reach up to above 80% under the full load) and very strong nonlinear load drive capacity, and simultaneously implement the inspection and monitoring to input voltage & current and output voltage & current |
|
| Technical Specifications. |
Pure Sine Wave Inverter NT Series Inverter 600w/1000w/1200w/1500w/2000w/3000w/4000w/5000w/6000w/10000W
1.Input
| Rated Capacity |
600W |
1000W |
1500W |
2KW |
3KW |
4KW |
5KW |
6KW |
10KW |
| Input Voltage |
110V Models |
220V Models |
| Nominal Voltage |
100/110/115/120V Selectable |
200/220/230/240v Selectable |
| Input Frequency |
47Hz ~ 65Hz, 50/60Hz auto-sensing |
| Efficiency |
95% (Normal mode) |
| Noise Filtering |
Fulltime EMI/RFI filtering |
| Over current protection |
By re-settable over current protector |
| Voltage Range |
-35% ~ +25% for selected nominal voltage. |
AVR Range (2 Bucks,2 Boosts) |
Enhanced Buck: +15% of selected nominal voltage Buck mode: +5% of selected nominal voltage Boost mode: -5% of selected nominal voltage Enhanced Boost: -12.5% of selected nominal voltage |
| Surge Protection |
324 Joules | 2.Output
| Model |
110V Models |
220V Models |
| Output Voltage |
100/110/115/120V Selectable |
200/220/230/240v Selectable |
| Waveform |
Sine wave |
| Crest Factor |
3:1 |
Output Frequency |
Auto Select for 50/60Hz 47Hz ~ 55Hz for 50Hz nominal; 56Hz ~ 65Hz for 60Hz nominal |
Regulation (Nominal) |
±10% typical of normal voltage (optional at ±8% AVR for wide I/P up to ±35%) |
| Regulation (Battery mode) |
±3% of selected output voltage (adjustable with the remote set-up software) |
| Transfer time |
Typical: 5ms (Including detection time) |
| Over current protection |
Over load alarm level 100% ~ 120%; Over load shutdown level 120% ~ 190% (Adjustable by using the remote set-up software) |
| Battery type |
Sealed ,maintenance-free lead acid |
| Voltage (DC) |
600W |
1KW |
1.5KW-2KW |
3KW-4KW |
5KW-6KW |
10KW |
| 12V |
12/24V |
24V |
48V |
96V |
192V |
Typical backup time |
Depend on external battery |
Charging method |
Smart pulse charging with two charging modes: Quick charging when battery is not fully charged, trickle charging when battery is 90% fully charged. |
| charging current |
15A for 3000w-1200w, 25A for1500w-10kw |
Average charging voltage for each battery |
Quick charging mode:14V maximum: Trickle charging mode:13.2V ~ 13.9V adjustable with the remote set-up software. |
| Protection |
Discharge, overcharge, and overload protection | 3.Communications Management
| Control panel |
LCD :UPS status, I/P&O/P Voltage Frequency, Load , Battery Voltage , Temperature , Model LED :Normal (Green), Warning (Yellow), Fault (Red) |
| Audible alarm |
Battery Mode : Beeping every 4 seconds Low Battery : Beeping every second Overload : Beeping twice per second |
Cooling fan control |
Auto on / off, controlled by temperature & operation mode |
| Operating Temperature |
Up to 1500 meters:0℃ to 40℃ (32℉ to 104℉) |
Transit/storage Temperature |
-20℃ to 55℃ |
| Relative Humidity |
0 - 95% non condensing |
| Operating Altitude |
0 ~ 3000 meters |
| Audible noise |
≦40 dBA at 1M |
| Safety Markings |
CE/FCC |
| EMC |
Class B, EN50091-2, FCC part15, IEC1000-2-2 |
| Quality system |
ISO 9001 | 4.Environmental and Safety Physical
| Size(H×D×W) mm |
600-1000w |
1000-1500w |
2000-4000w |
5000-10000w |
| 375*130*190 |
452*192*338 |
500*260*455 |
570*260*750 |
| N.W/ G.W(kg) |
9 |
12 |
23 |
24 |
36 |
49 |
55 |
67 |
| Packing |
Standard export package ;Neutral packing | |
|
 |
|