| Castle Series 3C10KS-3C20KS |
|
|
| |
High Frequency Online UPS Castle Series 3C10KS-3C20KS |
|
|
| |
Servers, Data centers, Critical network devices, Sensitive electronic equipment, Telecom. |
|
 |
| |
The best charger design to recharge low battery as quickly as possible with out damaging batteries in 2 amp up to 8 amp and 240 VDC. Allowing 90% recharge in as little as 10 Hours after a total drain. Audible and Visual Over-load indicators: The incorporated LED over load indicator prevents ups overloads and premature failure of the UPS. N+1 Parallel Redundancy: Allows a 6 kva to grow upto 18kva or 12kva with 6 kva redundancy and a 20 kva to 60 kva or 40 kva with 20 Kva redundancy allowing user to add capacity as needed and lower investment. Simplified board separation: Dependent on the Units all operation are separated into 5 pcb boards allowing quick respond to damages and provides our valued dealers with simplified inventory and faster service to the end users. Dynamic Bypass: Automatic dynamic Bypass and manual Bypass provide a loop to repair UPS with out having to disconnect loads ideal for non stop computing for critical applications. SNMP Slot: Provides remote monitoring and control of UPS where a PC is not present or where this function is needed to be separated. IBM AS 400 Dry Contact card: Optional card to communicate in IBM AS 400 Protols Sine-wave output: True sine-wave output with a 3% THD on batteries. This feature provides dependable and compatible power for your most critical applications. True double conversion technology with zero Transfer Time: This advance design provides the closest you can get to Pure constant power in the industry. |
|
 |
 |
| Technical Specifications. |
High Frequency Online UPS Castle Series UPS 3C10KS 3C15KS 3C20KS 10KVA 15KVA 20KVA Specifications 1.Output
| Capacity |
3C10KS |
3C15KS |
3C20KS |
| Rated Power |
10000VA/8000W |
15KVA/12KW |
20KVA/16KW |
| Output Voltage |
208VAC/220VAC/230VAC/240VAC |
| Voltage Waveform |
Pure Sine Wave |
| Crest Factor |
3:1 |
Output Frequency (Synchronized- Mains) |
46~54Hz Or 56Hz - 64Hz (Line Mode) 50/60HZ/ ±0.05Hz( Battery Mode) |
| Regulation(Nominal) |
±1% |
Regulation (Battery Mode) |
±1% |
| Transfer Time |
Zero |
| Over Current Protection |
Line Mode:10min@100%~130%;Battery Mode:30s@100%~130% |
| Outlet |
Hard Wiring With Terminal Block |
| Harmonic Distortion |
≤2%THD(Linear Load);≤5%THD(Non-Linear Load) | 2.Input
| Capacity |
3C10KS |
3C15KS |
3C20KS |
| Nominal Voltage |
277-520VAC@Full Load |
| Input Frequency |
46~54Hz / 56~60Hz |
| Efficiency |
90% (AC Mode) 90%(Battery Type) |
| Noise Filtering |
Full Time EMI/RFI Filtering |
| Over Current Protection |
By AC Fuse Or By Re-Settable Over Current Protector |
AVR Range (2 Bucks,2 Boosts) |
Enhanced Buck: +15% Of Selected Nominal Voltage Buck Mode: +5% Of Selected Nominal Voltage Boost Mode: -5% Of Selected Nominal Voltage Enhanced Boost: -12.5% Of Selected Nominal Voltage |
| Phase |
Three Phase Input and Single Phase Output | 3.Battery
| Battery Type |
Sealed Lead Acid Battery. |
| Rated Charging Voltage |
Depending On The Capacity Of External Batteries |
| Typical Backup Time |
Depending On The Capacity Of External Batteries |
| Charging Method |
Smart Pulse Charging With Two Charging Modes. Quick Charging When Battery Is Not Fully Charged, Trickle Charging When Battery Is 90% Fully Charged. |
| Charging Current(MAX) |
4.0/8.0A |
| Protection |
Over Current Protection & OverCharging Voltage Protection (SCRControl) Thermal Protection (CPU Control) When Temperature Inside UPS Is Over 45℃, Charger Will Stop Charging For 2.5 Minutes Followed By An 1.5 Minutes Charging. The Cycle Will BeRepeated Until The Temperature is Lower Than 44℃. |
Temperature Compension |
Yes |
| Numbers Of Battery |
DC192V, Depending On The Capacity Of External Batteries | 4.Optional Features
| ECO Mode |
Support |
| CVCF |
Support |
| PDU |
Support |
| Remote Panel |
Wired Type, Up To 100M Length |
| Parallel Redundancy |
Up To 4 Units Max (Option) | 5.Environmental And Safety
| Operating Temperature |
0℃ To 40℃ (32℉ To 104℉) |
Transit/Storage Temperature |
-15℃ To 55℃ (5℉ To 131℉) |
| Relative Humidity |
20-90%(NON-CONDENSING) |
| Operating Altitude |
0 ~ 3000 Meters |
| Audible Noise |
≦50 Dba |
| Safety Markings |
BSMI |
CE |
| EMC |
Class B, EN50091-2, FCC Part15, IEC1000-2-2 |
| Quality Control System |
ISO 9001:2000 |
| Noise Level |
<60db@1 Meter | 6.Indicator
| LED Version |
Load Level/Battery Level/Battery Mode; AC Mode/Bypass Mode/Fault |
| Battery Mode |
Sounding Every 4 Seconds |
| Low Battery |
Sounding Every Second |
| Overload |
Sounding Twice Every Second |
| Fault |
Continously Sounding |
| LCD Version |
Load/Battery/Input/Output/Operating;Mode Information | 7.Interface
| Smart RS-232 |
Software Supports Windows Family. Sun Solaris, IBM Aix, Compaq True64,SGIIRIX ,Freebsd.HP-UX, And MAC |
| USB (Option) |
Windows Family& MAC |
| Internal Slot(Option) |
SNMP/AS400 Relay Card/Rs485 (Option) |
| EPO(Option) |
Support Emergency Shutdown | 8.Physical
Dimensions: (D×H×W)mm |
595*390*578mm |
| N.W/G.W (Kg) |
3C10KS:27 |
3C15KS:35 |
3C20KS:35 |
| Packing |
Standard Packing, Export Carton For Each Unit | |
|
 |
|